When leak testing a low pressure centrifugal with nitrogen, what is the maximum test pressure? Show
Charged low pressure refrigeration machines may be most efficiently checked by: C. Raising system pressure by heating with circulated hot water or heating blankets EPA regulations require that all appliances containing more than 50
lbs of refrigerant (except for commercial and industrial process refrigeration) be repaired when the leak rate exceeds_______ % of the charge per year A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low pressure chiller is: R 11 or R 123 system refrigerant removal starts with: With a low pressure chiller, what must you do after recovering the liquid refrigerant? A. Recover the vapor refrigerant When removing oil from a low pressure system, the temperature should be 130F because: B. Less refrigerant will be contained in the oil at the higher temperature According to ASHRAE guideline 3-1996, if the pressure in a system rises from 1mm hg to a level above______ during a standing vacuum test, the system should
be checked for leaks. After system servicing, why is refrigerant vapor re-introduced to the refrigeration system before refrigerant liquid? D. Liquid charge into a deep vacuum will boil and may lower temperatures enough to freeze water in the tubes Appliances need not be evacuated all the way to the prescribed level
when: C. Leaks in the appliance make evacuation to the prescribed level unattainable Which of the following repairs would ALWAYS be considered "major" under EPA's regulations? A. Replacement of an evaporator coil After reaching the required recover vacuum on an appliance, you should: B. Wait for at least a few minutes to see if the system pressure rises, indicating that there is still refrigerant in liquid form or in the oil Which of the following WOULD NOT fall under the EPA definition for "Major maintenance -service -or repair"? A. Replacing an oil filter When using recovery or recycling equipment manufactured BEFORE Nov 15th, 1993, technicians must evacuate low pressure appliances to the
following level before making a major repair: Under EPA's regulations, which of the following methods can be used to pressurize an R11 or R123 system for the purpose of opening the system for a non-major repair? During vapor removal from a low pressure refrigeration system: C. The water pumps, the recovery compressor, and the recovery condenser water should all be on The PRIMARY purpose of a purge pump unit on a CFC 11 chiller is to: D. Remove non-condensable from the system Under what code group of ASHRAE standard 34 does R123 fall? Which of the following safety precautions
should be adhered to for low pressure systems? When recharging a refrigeration system with R11, what vapor pressure is necessary in the shells before charging with liquid? A centrifugal chiller's rupture disk is connected to the chillers: On a centrifugal system, the purgeunit takes its suction from the: A rupture disk on a recovery vessel for low pressure refrigerants relieves at: Approximately how much refrigerant vapor is left in an average 350 ton R11 chiller at 0 psig pressure once all of the R11 liquid has been removed? What is the primary water source for a recovery unit condensing coil? Which of the following repairs would always be considered major under EPA's regulations?the system water pumps, the recovery compressor, and the recovery condenser water should all be on. Which of the following repairs would ALWAYS be considered "major" under EPA's regulations? Replacement of an evaporator coil.
What steps may be taken to prevent air accumulation?What steps may be taken to prevent air accumulation into an idle low-pressure refrigeration system? Leave the purge unit on-line at all times. Maintain system pressure slightly above atmospheric pressure. Open the air vents on the condenser.
Which of the following methods can be used to pressurize an R 1233zd system for the purpose of opening the system for a non major repair quizlet?Which of the following methods can be used to pressurize an R-1233zd system for the purpose of opening the system for a non-major repair? warming the liquid refrigerant in the system .
Which of the following safety precaution should be adhered to for low pressure systems?The following safety precautions should be adhered to for low pressure systems: Do not siphon refrigerant by mouth .. dummy. Avoid spilling liquid refrigerant on your skin.
|